The reverse engineering tool for ETS2 (ETS2 auxiliary module)
| Version | 1.6.103 |
| Language | English / German |
| Media | Floppy disks 3.5" |
| Operating System | Windows 98,ME,NT4.0,2000,XP |
| Compatibility | ETS2 1.2 to 1.3 |
This product has been superseded by Reconstruction
for ETS 3.
This provides many new functions and can reconstruct devices which could be reconstruct by
Reconstruction for ETS 2 not at all, not completely or only very slowly.
You may use Reconstruction for ETS 3 also if the installation was orginally put into operation
with ETS 2.
Description
- Full or partial reading out of programmed devices of an EIB system (with all parameter settings, group address assignments)
- Comparison of read-out data with the project planning data
- Conversion of read-out data into a ETS project.
In this way lost or unavailable project planning data may be restored. - ETS1 versions from 1.3 onwards and all ETS2 versions are supported.
A free demo version with the following limitations is available.
- Although all phys. addresses are read out, only 50% of the devices (maximum
however 20 devices). - A max. of 20 devices may be reconstructed.
- The "Merge" and "Compare" functions are not available.
You may download the demo here.
Details
This data can be recovered:
- Topology (areas and lines)
- Devices
- Individual address
- Used application program
- Parameter settings
- Communication object flags and priority
- Assigned group addresses
This data is not programmed into the devices and therefore cannot be recovered:
- Building and function structure
- Names and descriptions of areas, lines, devices and group addresses
Restrictions: In some cases, reconstruction might fail or finish incomplete:
- Devices locked with an unknown BCU password cannot be read.
- Devices that are programmed with an ETS Plug-in, are not supported by Reconstruction for ETS 2 (but many are supported by Reconstruction for ETS 3).
- Devices with segmented memory (mask versions $0700, $0701, $0705, $071B etc.) are not supported (but are supported by Reconstruction for ETS 3).
- Some application programs contain parameters that are not programmed into the device (e.g. comments for documentation). These functionally ineffectual parameters can therefore not be recovered.
- It is possible that application programs exist with complex parameter interdependencies that cannot be resolved by IT Reconstruction (the message "Parameter reconstruction incomplete" will appear).